The choice of valves depends on the device type being used. The electronics converts an external standard signal into a pulsewidth modulated pwm signal with which the opening of the proportional valve and hence a. Pin out for both connection versions can be referenced in the 8605 operating manual. Burkert 8605 operating instructions manual pdf download.
Control electronics type 8605, cable plug with pgconnection. Directacting 2 way standard solenoid control valve burkert usa. Low hysteresis, high reproducibility and good response sensitivity guarantee good positioning behaviour. Field of application the control electronics, type 8605, is designed for continuous operation in industrial environments, in particular in the fields. The control electronics, type 8605, is suitable for the control of all burkert proportional. Due to an elastomeric seat seal the valve closes tight integrated shutoff function, up to the dn specific nominal pressure. The valve type 6223 can be used for the control of larger flow quantities. It has input signal options of 020 ma, 420ma or 05v, 010 v configurable. This 4digit code is to found on the last page of these operating instructions. A contactfree analogue position sensor measures the position of the valve spindle. Type 8611 econtrol universal controller burkert fluid. It converts an external input signal, 05 v, 010 v, 020 ma or 420ma, into a pulse width modulated pwm signal to control the plunger position of the solenoid valve. We have 2 burkert 8605 series manuals available for free pdf download. Controller burkert 8681 operating instructions manual 90 pages.
Buy now type description the digital control electronics, typeserves to operate proportional solenoid control valves in the power range from 40 ma. Digital control electronics for proportional valves. The compact process controller type 8693 is optimized for integrated mounting on the pneumatic actuators in the process valve series type 23xx2103 and is specially designed for the requirements of a hygienic process environment. When considering the cable plug housing style, the current range of the. The burkert type 8605 is a digital controller used to control proportional solenoid valves within a power range of 40 2,000 ma. Close tight function characteristic curves selection reversal of. Whether the application is filling, level, flow, pressure or temperature we have a solution and a uniquely comprehensive range of products to. The plunger of the valve is assembled frictionless, which leads to an extraordinary adjustment characteristic. Apr 22, 2019 burkert type 8605 user manual show articles type description the digital control electronics, typeserves to operate proportional solenoid control valves in the power range from 40 ma. Technical manual 14731 8605 3 1 notes on the instruction manual please read this manual through carefully and adhere to the information contained therein. The actual value of the process factor is directly supplied to the device as 420 ma, pt100 or a frequency signal. Type 8605 pwm control electronics for electromagnetic.
The digital control electronics, type 8605, serves to operate proportional solenoid control valves in the power range from 40 2000 ma. Proportional pwm controller 1224v dc dina pg burkert. The electronics convert an external standard signal into a pulsewidth modulated pwm signal, which enables infinite adjustment of the opening of the proportional. The directacting solenoid control valve type 2875 is used as the regulating unit in control loops. Type 8802 element continuous control valve systems burkert.
Burkert type 8605 digital control electronics, serves to operate valves in the power range from 40 2000 ma. In a completely different league at a fraction of the cost of traditional i to p style pancake control valves, burkerts new oem positioner gives exceptional value while maintaining unmatched. The easy handling and the selection of additional software functions are done either on a big. The 8605 controller in conjunction with a speed sensor, flowmeter, and servo valve performs the. Burkert 8605 digital control electronics for proportional valves 200 ma. Burkert type 8605 training video with closed captioning. The electronics converts an external standard signal into a pulsewidth modulated pwm signal with which the opening of the valve and hence a fluidic output parameter e. Burkert 8605 series operating instructions manual 118 pages digital control electronics for proportional valves. Lelettronica di controllo digitale tipo 8605 viene utilizzata per il comando di elettrovalvole proporzionali nel campo di potenza 402000 ma. The 8605 controller allows you to set up a system individually calibrated to your speci. Proportional pwm controller 24v dc din rail burkert 8605.
Store this manual in such a way that is easily accessible to every user and is available to every new owner of the device. Burkert 2875 solenoid control valve with 8605 digital. Type 8605 control electronics for solenoid control valves. The electronics convert an external standard signal into a pulsewidth modulated pwm signal, which enables infinite adjustment of the opening of the proportional valve and hence a fluidic output parameter e. The digital control electronics, burkert type 8605, serves to operate proportional solenoid control valves in the power range from 40 2000 ma. Burkert 8694 oem positioner for water, process or steam. Type 8630 fine controls uk ltd fine controls uk ltd. Burkert type 8605 training video with closed captioning youtube.
Burkert 178354 type 8605 control electronics for solenoid. Initialization of control top on a burkert valve youtube. Man, supplement type 8605 2836 2861 2863 2865 2871 2873 2875 6024 6223. The electronics converts an external standard signal into a pulsewidth modulated pwm signal with which the opening of the proportional valve and hence a fluidic output parameter e. A display and operating keys allow the electronics to be easily adapted to a particular proportional valve and to the specific conditions of an application. Supplement type 8605 2836 2861 2863 2865 2871 2873 2875 6024 6223.
Simple installation through automatic tunefunction and setting through dipswitch. Controller burkert 8681 quick start manual 92 pages. This valve is particularly suitable for demanding control. These instructions also include the warranty provisions and details about the correct disposal of the device. Show articles type description the digital control electronics, typeserves to operate proportional solenoid control valves in the power range from 40 ma. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device.
The compact positioner type 8692 is optimized for integrated mounting on the pneumatic actuators in the process valve series type 23xx2103 and is specially designed for the requirements of a hygienic process environment. Failure to observe this operating manual and its operating instructions as well as unauthorized tampering. Operating instructions type 8611 from software version b02, 3 mb, en eu. The burkert flow controller module has a pwm control output and cable plug type electrical connection. Industrial electrical burkert ptb 03 atex 1030 x operating instructions manual. Type 2836 directacting 2way solenoid control valve. Operating instructions, type 8605 read online or download pdf burkert type 8605 user manual.
Metex corporation is a distributor of burkert products. Devices without a separate ex rating plate may not be used in a potentially explosive area. A burkert advanced technical training for setup of the type 8605 position controller setup. Read online or download pdf page 25 108 burkert type 8605 user manual burkert accessories for water. View online or download burkert 8605 series operating instructions manual. Pwm control electronics for solenoid control valves burkert. Burkert 8605 series operating instructions manual pdf. Read online or download pdf page 24 108 burkert type 8605 user manual burkert accessories for water. View and download burkert 8605 operating instructions manual online.
Field of application the control electronics, type 8605, is designed for continuous operation in industrial environments, in particular in the fields of openloop and closedloop control engineering. It operates solenoid valves in the power range from 40ma to 2000ma. The digital control electronics, typeserves to operate proportional solenoid control valves in the power range from 40 ma. Compact positioner for integrated mounting on pneumatically operated process valves. Burkert fluid control systems canada can be used wherever fluid media and gases need to be measured, controlled and regulated. It transforms an external standard signal into a pulsewidth modulated voltage signal pwm that is supplied to the. Type 2875 directacting 2 way standard solenoid control.
The hiniker 8605 controller is a computerized system that will enable you to apply liquid chemicals, including anhydrous ammonia at any given rate. Industrial electrical burkert 8605 series operating instructions manual 82 pages. It has input signal options of 020 ma, 420ma or 05v, 010 v. Proportional pwm controller 1224v dc dina m12 burkert. The control air channel is integrated in the actuator without external tubings. The operating instruction has to be read and understood read the operating manual through carefully. Download burkert 8605 operating instructions manual. Operation of this device can be locked by means of a freely selectable user code. Operating instructions type ac10 solenoid coil hazloc, 2 mb, en eu. Valve with plastic body, manual override and cable plug uc with silicon cable, please see footnote.
This burkert quick tip demonstrates how to initialize a control top on a burkert process valve. View and download burkert 8605 series operating instructions manual online. Independent of this, there exists an unchangeable master code with which you can execute all operative actions on the device. The design of the system type 8802 continuous element enables the easy integration of digital automation modules whether they are simple positioner basic, highcapacity positioner with optional integrated fieldbus interface or even a digital process controller with easy handling thanks to the backlighting of the graphics display. Type 8605 controls all burkert proportional valves with a max. Remote setpoint adjustment via a 4 20 ma signal or through asinterface. The digital control electronics type 8605 are used to operate proportional solenoid control valves in a power range from 402000 ma. It is compatible and tested with all burkert proportional valves and sensors and can be connected with every nonburkert control valve by standard signal 420 ma.